Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Quant Imaging Med Surg ; 13(8): 4908-4918, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37581062

ABSTRACT

Background: Hepatic acute graft-versus-host disease (aGVHD) is a major life-threatening complication of allogeneic hematopoietic stem cell transplantation (allo-HSCT). We hypothesized that contrast-enhanced ultrasound (CEUS) could serve as a new imaging biomarker in early diagnosis of hepatic aGVHD by detecting liver microcirculation. Methods: Thirty Wistar rats received allo-HSCT were finally included after excluding 9 rats, and they were randomly divided into 5 groups (1- to 5-week groups, 6 per group). Six rats were used for the control group without any intervention. We observed the clinical scores, serum liver enzyme levels and liver CEUS parameters of rats in each group. Hepatic aGVHD was finally confirmed by histopathologic analysis. The diagnostic performance of CEUS parameters in detecting GVHD was evaluated by comparing the area under the receiver operating curve (AUC) values. Results: After HSCT, the rats developed ruffling of fur, maculopapular rash, weight loss, accompanied by increased clinical scores. Serum liver enzymes were significantly higher than those in the control group from the third week, especially alkaline phosphatase, while CEUS parameters, peak intensity (PI) and mean transit time (MTT), changed in the second week (P<0.001). Compared with non-aGVHD group, the PI was significantly decreased while time to peak and MTT were prolonged in aGVHD group. CEUS parameters were more strongly correlated with pathological grade than serology. PI was an independent predictor for hepatic aGVHD. The AUC of CEUS parameters for diagnosing hepatic aGVHD was 0.933 (95% CI: 0.779-0.992), which was higher than that of clinical scores (AUC =0.748, 95% CI: 0.557-0.888, P=0.032) and serological markers (AUC =0.902, 95% CI: 0.737-0.980, P=0.694). Conclusions: CEUS exhibits promising applications as a quantitative method to detect hepatic aGVHD and early liver damage.

2.
Quant Imaging Med Surg ; 13(4): 2183-2196, 2023 Apr 01.
Article in English | MEDLINE | ID: mdl-37064382

ABSTRACT

Background: When users inquire about knowledge in a certain field using the internet, the intelligent question-answering system based on frequently asked questions (FAQs) provides numerous concise and accurate answers that have been manually verified. However, there are few specific question-answering systems for chronic diseases, such as rheumatoid arthritis, and the related technology to construct a question-answering system about chronic diseases is not sufficiently mature. Methods: Our research embedded the classification information of the question into the sentence vector based on the bidirectional encoder representations from transformers (BERT) language model. First of all, we calculated the similarity using edit distance to recall the candidate set of similar questions. Then, we took advantage of the BERT pretraining model to map the sentence information to the corresponding embedding representation. Finally, each dimensional feature of the sentence was obtained by passing a sentence vector through the multihead attention layer and the fully connected feedforward layer. The features that were stitched and fused were used for the semantic similarity calculation. Results: Our improved model achieved a Top-1 precision of 0.551, Top-3 precision of 0.767, and Top-5 precision of 0.813 on 176 testing question sentences. In the analysis of the actual application effect of the model, we found that our model performed well in understanding the actual intention of users. Conclusions: Our deep learning model takes into account the background and classifications of questions and combines the efficiency of deep learning technology and the comprehensibility of semantics. The model enables the deep meaning of the user's question to be better understood by the intelligent question answering system, and answers that are more relevant to the original query are provided.

3.
Quant Imaging Med Surg ; 12(11): 5044-5055, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36330177

ABSTRACT

Background: To investigate the feasibility of using shear wave dispersion (SWD) imaging to evaluate hepatic acute graft-versus-host disease (aGVHD) in a rat model. Methods: To establish an aGVHD model, 30 Wistar rats were subjected to bone marrow transplantation, 10 Fischer 344 rats were used as donors, and 6 Wistar rats were used as the control group. Each week, 6 rats were randomly chosen and divided into groups of 1 week (1 w) to 5 weeks (5 w). For each subgroup, the rats received a clinical index assessment and shear wave dispersion (SWD) examination with 2 quantitative values, shear wave (SW) speed and SWD slope. The histological characteristics were then used as the reference standard to divide the rats into the aGVHD group and the no aGVHD (nGVHD) group. Results: In the 2 weeks (2 w) group, only SWD slope [median: 7.26, interquartile range (IQR): 7.04 to 7.31] showed a significant increase in the measured value (P<0.05). The value of the 3 weeks (3 w) group (median: 7.88, IQR: 7.84 to 8.49) significantly increased compared with the 2 w value (P<0.05). Although the value increased gradually from week 3 to week 5, it had no statistical significance (P>0.05). The SW speed [mean ± standard deviation (SD): 1.54±0.11, 95% confidence interval (CI): 1.48 to 1.59] and SWD slope (mean ± SD: 8.29±0.56, 95% CI: 7.99 to 8.59) of the aGVHD group were higher than those of the control group and the nGVHD group (P<0.001). The correlation of SWD slope with pathological grade was the highest (r=0.798, P<0.01), followed by SW speed (r=0.785, P<0.01), and the correlation of clinical index with pathological grade was the lowest (r=0.751, P<0.01). In addition, the area under the receiver operating characteristic (ROC) curve (AUC) value of aGVHD using the SWD slope was 0.844 (95% CI: 0.67 to 0.95, sensitivity: 93.75%, specificity: 78.57%), which was higher than the AUC of both SW speed and clinical index, and the difference was statistically significant compared to the AUC of the clinical index. Conclusions: The SWD slope could show significant abnormalities earlier than SW speed and clinical index and is also more consistent with the change in aGVHD severity level. The SWD slope may help in detecting hepatic aGVHD during ultrasound SWD examination.

4.
Quant Imaging Med Surg ; 12(1): 184-195, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34993070

ABSTRACT

BACKGROUND: Rheumatoid arthritis (RA) is a disease of the immune system with a high rate of disability and there are a large amount of valuable disease diagnosis and treatment information in the clinical note of the electronic medical record. Artificial intelligence methods can be used to mine useful information in clinical notes effectively. This study aimed to develop an effective method to identify and classify medical entities in the clinical notes relating to RA and use the entity identification results in subsequent studies. METHODS: In this paper, we introduced the bidirectional encoder representation from transformers (BERT) pre-training model to enhance the semantic representation of word vectors. The generated word vectors were then inputted into the model, which is composed of traditional bidirectional long short-term memory neural networks and conditional random field machine learning algorithms for the named entity recognition of clinical notes to improve the model's effectiveness. The BERT method takes the combination of token embeddings, segment embeddings, and position embeddings as the model input and fine-tunes the model during training. RESULTS: Compared with the traditional Word2vec word vector model, the performance of the BERT pre-training model to obtain a word vector as model input was significantly improved. The best F1-score of the named entity recognition task after training using many rheumatoid arthritis clinical notes was 0.936. CONCLUSIONS: This paper confirms the effectiveness of using an advanced artificial intelligence method to carry out named entity recognition tasks on a corpus of a large number of clinical notes; this application is promising in the medical setting. Moreover, the extraction of results in this study provides a lot of basic data for subsequent tasks, including relation extraction, medical knowledge graph construction, and disease reasoning.

5.
J Ultrasound Med ; 41(3): 617-626, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33938029

ABSTRACT

OBJECTIVES: This study aimed to determine ultrasonic image characteristics that enable differentiation between cholesterol and adenomatous polyps and to assess the diagnostic efficacy of combining conventional ultrasound (CUS) with contrast-enhanced ultrasound (CEUS). METHODS: Eighty-nine patients with gallbladder polyps of 1-2 cm in diameter were enrolled and examined by CUS and CEUS before cholecystectomy. The appearances on CUS and CEUS were recorded and analyzed. The receiver operating characteristic (ROC) curve was used to calculate the optimal size threshold for distinguishing cholesterol from adenomatous polyps. A logistic regression analysis was performed to identify diagnostic variables. ROC analysis was performed to evaluate the diagnostic efficacy of the size, the independent variables, and the combined factors. RESULTS: There were differences in size, number, vascularity on CUS and intralesional vascular shape, wash-out, and area under the curve on CEUS between the two groups (P < .05). ROC analysis indicated that a maximum diameter of 1.45 cm was the optimal threshold for the prediction of adenomatous polyps. The logistic regression analysis proved that the single polyp, presence of vascularity, and intralesional linear vessels were associated with adenomatous polyps (P < .05). ROC analysis showed that the area under the ROC curve, sensitivity, and specificity for the combination of the three independent variables were 0.858, 87.3%, and 67.6%. The number combined with intralesional vascular shape had the highest diagnostic sensitivity of 91.2%. CONCLUSIONS: The combination of CUS and CEUS demonstrated great significance in the differential diagnosis of cholesterol and adenomatous polyps.


Subject(s)
Adenomatous Polyps , Gallbladder Neoplasms , Polyps , Adenomatous Polyps/diagnostic imaging , Cholesterol , Contrast Media , Diagnosis, Differential , Gallbladder Neoplasms/diagnosis , Humans , Polyps/diagnostic imaging , Ultrasonography
6.
Quant Imaging Med Surg ; 11(5): 2052-2061, 2021 May.
Article in English | MEDLINE | ID: mdl-33936986

ABSTRACT

BACKGROUND: It is challenging to differentiate between phyllodes tumors (PTs) and fibroadenomas (FAs). Artificial intelligence (AI) can provide quantitative information regarding the morphology and textural features of lesions. This study attempted to use AI to evaluate the ultrasonic images of PTs and FAs and to explore the diagnostic performance of AI features in the differential diagnosis of PTs and FAs. METHODS: A total of 40 PTs and 290 FAs <5 cm in maximum diameter found in female patients were retrospectively analyzed. All tumors were segmented by doctors, and the features of the lesions were collated, including circularity, height-to-width ratio, margin spicules, margin coarseness (MC), margin indistinctness, margin lobulation (ML), internal calcification, angle between the long axis of the lesion and skin, energy, grey entropy, and grey mean. The differences between PTs and FAs were analyzed, and the diagnostic performance of AI features in the differential diagnosis of PTs and FAs was evaluated. RESULTS: Statistically significant differences (P<0.05) were found in the height-to-width ratio, ML, energy, and grey entropy between the PTs and FAs. Receiver operating characteristic (ROC) curve analysis of single features showed that the area under the curve [(AUC) 0.759] of grey entropy was the largest among the four features with statistically significant differences, and the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 0.925, 0.459, 0.978, and 0.190, respectively. When considering the combinations of the features, the combination of height-to-width ratio, margin indistinctness, ML, energy, grey entropy, and internal calcification was the most optimal of the combinations of features with an AUC of 0.868, and a sensitivity, specificity, PPV, and NPV of 0.734, 0.900, 0.982, and 0.316, respectively. CONCLUSIONS: Quantitative analysis of AI can identify subtle differences in the morphology and textural features between small PTs and FAs. Comprehensive consideration of multiple features is important for the differential diagnosis of PTs and FAs.

7.
Quant Imaging Med Surg ; 10(3): 754-765, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32269934

ABSTRACT

BACKGROUND: Shear wave elastography is a promising method to diagnose early musculoskeletal lesions. We aimed to explore the feasible depth and acceptable precompression applied by probe and couplant for soft tissues in the present system. METHODS: Ex-vivo muscles were evaluated at depths of 0.5-6 cm by 3 operators, using 1-5 mm couplant thickness and 0-3.0 kPa probe pressure. We compared the shear wave speed (SWS) and used intraclass correlation coefficients to assess reproducibility. In vivo skin and subcutaneous superficial fascia from volunteers were tested at depths ranging from 0.1-0.5 cm with 1-20 mm couplant thickness. RESULTS: The SWS of ex-vivo muscles varied and increased with depth, and could not be acquired at 6 cm because the shear wave failed to be detected. Furthermore, while the SWS of ex-vivo muscles were not affected by the couplant thickness, it was affected by probe pressure. Most cases demonstrated a satisfactory agreement degree of the intraoperator reproducibility (ICC, 0.81-0.95) and a substantial interoperator reproducibility (ICC >0.60). Inter- and intra-operator reproducibility was better at a depth of 0.5-4 cm than at 5 cm. In the in vivo study, when tissues within a 0.2 cm depth were evaluated, the SWS that was acquired using a couplant thickness of >10 mm was different from that acquired using other thicknesses. CONCLUSIONS: The SWS acquired at a depth of ≤3 cm with a suitable amount of couplant is recommended.

8.
Nucleic Acids Res ; 48(D1): D320-D327, 2020 01 08.
Article in English | MEDLINE | ID: mdl-31906602

ABSTRACT

Liquid-liquid phase separation (LLPS) leads to a conversion of homogeneous solution into a dense phase that often resembles liquid droplets, and a dilute phase. An increasing number of investigations have shown that biomolecular condensates formed by LLPS play important roles in both physiology and pathology. It has been suggested the phase behavior of proteins would be not only determined by sequences, but controlled by micro-environmental conditions. Here, we introduce LLPSDB (http://bio-comp.ucas.ac.cn/llpsdb or http://bio-comp.org.cn/llpsdb), a web-accessible database providing comprehensive, carefully curated collection of proteins involved in LLPS as well as corresponding experimental conditions in vitro from published literatures. The current release of LLPSDB incorporates 1182 entries with 273 independent proteins and 2394 specific conditions. The database provides a variety of data including biomolecular information (protein sequence, protein modification, nucleic acid, etc.), specific phase separation information (experimental conditions, phase behavior description, etc.) and comprehensive annotations. To our knowledge, LLPSDB is the first available database designed for LLPS related proteins specifically. It offers plenty of valuable resources for exploring the relationship between protein sequence and phase behavior, and will enhance the development of phase separation prediction methods, which may further provide more insights into a comprehensive understanding of LLPS in cellular function and related diseases.


Subject(s)
Databases, Protein , Proteins/chemistry , Hydrogen-Ion Concentration , Internet , User-Computer Interface
9.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 38(3): 341-5, 2016 06 10.
Article in English | MEDLINE | ID: mdl-27469923

ABSTRACT

Objective To investigate the correlation between ultrasound-guided diffuse optical tomography (US-DOT) and hypoxia-inducible factor-1Α (HIF-1Α) of breast cancer. Methods Totally 69 patients with pathologically confirmed breast cancer underwent preoperative conventional breast ultrasonography examinations and US-DOT at Peking Union Medical College Hospital From October 2007 to February 2010 were enrolled in this study.After surgery,immunohistochemical staining of HIF-1Α and CD34 were performed,and the differences of total hemoglobin concentration (THC) and microvessel density (MVD) between HIF-1Α positive and negative groups were analyzed. Results HIF-1Α was positive in 12 cases (17.4%) and negative in 57 cases (82.6%). The average THC and MVD of HIF-1Α-positive cases were (274.763±77.661) Μmol/L and (33.8±10.8)/0.2 mm(2) respectively. The average THC and MVD of HIF-1Α-negative cases were (228.059±65.760)Μmol/L and (28.4±7.4)/0.2 mm(2). MVD(t=2.049,P=0.04) and THC(t=2.167,P=0.034) of HIF-1Α-positive group were significantly higher than those of HIF-1Α-negative group. Conclusions HIF-1Α can promote tumor angiogenesis and thus increase the blood supply and THC. As an indicator of tumor blood supply,THC can indirectly reflect the angiogenic activity of breast cancer.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/metabolism , Hypoxia-Inducible Factor 1, alpha Subunit/metabolism , Tomography, Optical , Ultrasonography, Mammary , Female , Humans , Neovascularization, Pathologic
10.
J Diabetes Investig ; 5(6): 734-42, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25422776

ABSTRACT

AIMS/INTRODUCTION: To compare carotid and lower limb atherosclerotic lesions, and examine if carotid atherosclerotic lesions are in line with lower limb atherosclerotic lesions, and can reflect generalized atherosclerosis in inpatients with type 2 diabetes. MATERIALS AND METHODS: This was an observational study carried out in 867 Chinese inpatients with type 2 diabetes, including 573 previously known and 294 newly diagnosed patients. Ultrasonographic assessments of intima-media thickness (IMT), plaques, and stenosis in the carotid and lower limb arteries were evaluated. Atherosclerotic lesions between the carotid and lower limb arteries were compared in both previously known and newly diagnosed diabetes, respectively. RESULTS: In both the known (77.3% vs 49.4%, P < 0.001) and the newly diagnosed diabetes (55.4% vs 29.9%, P < 0.001), the prevalence of atherosclerotic plaques was significantly higher in the lower limb arteries than in the carotid arteries. Likewise, the prevalence of stenosis was also significantly higher (P < 0.001) in the lower limb arteries (16.9%) than in the carotid arteries (4.2%) in the established diabetes patients. However, there was no significant difference in the mean IMT between common carotid and common femoral arteries in both the previously known (0.90 ± 0.24 mm vs 0.89 ± 0.20 mm, P = 0.675) and the newly diagnosed diabetes patients (0.86 ± 0.22 mm vs 0.85 ± 0.16 mm, P = 0.436). CONCLUSIONS: Carotid plaques might underestimate generalized plaques in inpatients with type 2 diabetes, as shown by its significantly lower prevalence compared with that of the lower extremity arteries. A combined carotid and lower limb ultrasound examination can improve the detection of atherosclerotic lesions in inpatients with type 2 diabetes.

11.
Acta Pharmacol Sin ; 35(9): 1150-6, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25087999

ABSTRACT

AIM: Considering the characterization of vitamin D deficiency as a risk factor of ectopic fat deposition, the association of serum 25-hydroxy vitamin D3 [25(OH)D3] levels with non-alcoholic fatty liver disease (NAFLD) was evaluated in Chinese men with normal body mass index (BMI) and enzyme markers of liver function. METHODS: A total of 514 participants (22 to 79 years old) with normal BMI and liver enzymes were identified for analysis. Abdominal ultrasound was performed to diagnose NAFLD, and the fatty liver index (FLI) was calculated to quantify liver steatosis. Serum 25(OH)D3 levels were determined by an electrochemiluminescence immunoassay. RESULTS: Among the entire study population, the mean levels of serum 25(OH)D3 were 15.32±5.77 ng/mL. However, when serum 25(OH)D3 levels were compared between non-NAFLD subjects (n=438) and NAFLD subjects (n=76), the latter showed significantly lower levels (15.65±5.89 ng/mL vs 13.46±4.65 ng/mL, P=0.002). In addition, serum 25(OH)D3 levels were found to be significantly correlated with FLI after adjustment for age and BMI (r=-0.108, P=0.014). Logistic regression showed that serum 25(OH)D3 levels were independently correlated with NAFLD (OR: 0.937, 95% CI: 0.884-0.993, P=0.028). Furthermore, stepwise regression analysis revealed that serum 25(OH)D3 levels were inversely associated with FLI (ß=-0.055, P=0.040). CONCLUSION: The present study demonstrated that serum 25(OH)D3 levels were inversely associated with NAFLD, even in subjects with normal total body fat, suggesting a potential role of lower levels of vitamin D in the occurrence and development of NAFLD.


Subject(s)
Non-alcoholic Fatty Liver Disease/blood , Vitamin D/blood , Adult , Aged , Asian People , Humans , Liver/enzymology , Liver/metabolism , Male , Middle Aged , Non-alcoholic Fatty Liver Disease/metabolism , Vitamin D/metabolism , Young Adult
12.
Pharm Res ; 31(6): 1477-84, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24718918

ABSTRACT

PURPOSE: To develop a multimodal imaging guided and triggered drug delivery system based on a novel emulsion formulation composed of iron oxide nanoparticles, nanoscopic bubbles, and oil containing drugs. METHODS: Iron oxide paramagnetic nanoparticles were synthesized and modified with surface conjugation of polyethylenimide (PEI) or Bovine Serum Albumin (BSA). Both particles were used to disperse and stabilize oil in water emulsions containing coumarin-6 as the model drug. Sulfur hexafluoride was introduced into the oil phase to form nanoscopic bubbles inside the emulsions. The resulted gas containing emulsions were evaluated for their magnetic resonance (MR) and ultrasound (US) imaging properties. The drug release profile triggered by ultrasound was also examined. RESULTS: We have successfully prepared the highly integrated multi-component emulsion system using the surface modified iron oxide nanoparticles to stabilize the interfaces. The resulted structure had distinctive MR and US imaging properties. Upon application of ultrasound waves, the gas containing emulsion would burst and encapsulated drug could be released. CONCLUSION: The integrated emulsion formulation was multifunctional with paramagnetic, sono-responsive and drug-carrying characteristics, which may have potential applications for disease diagnosis and imaging guided drug release.


Subject(s)
Contrast Media/chemistry , Drug Carriers/chemistry , Drug Delivery Systems , Emulsions , Magnetite Nanoparticles/chemistry , Animals , Chemistry, Pharmaceutical , Coumarins/administration & dosage , Coumarins/pharmacokinetics , Gases , Liver/metabolism , Rats , Thiazoles/administration & dosage , Thiazoles/pharmacokinetics , Tissue Distribution , Ultrasonics
13.
J Clin Nurs ; 23(5-6): 837-43, 2014 Mar.
Article in English | MEDLINE | ID: mdl-23710585

ABSTRACT

AIMS AND OBJECTIVES: To investigate the incidence and risk factors for peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer. BACKGROUND: With the widespread use of peripherally inserted central venous catheters, peripherally inserted central venous catheters-related upper extremity venous thrombosis in patients with cancer leads to increasing morbidity and mortality. It is very important to further explore the incidence and risk factors for peripherally inserted central venous catheters-related venous thrombosis. DESIGN AND METHODS: Consecutive patients with cancer who were scheduled to receive peripherally inserted central venous catheters, between September 2009 and May 2012, were prospectively studied in our centre. They were investigated for venous thrombosis by Doppler sonography three times a day within 30 days after catheter insertion. Univariable and multivariable logistic regressions' analyses were performed to identify the risk factors for peripherally inserted central venous catheters-related thrombosis. RESULTS: A total of 89 patients with cancer were studied in our research. Of these, 81 patients were followed up within one month. The mean interval between catheter insertion and the onset of thrombosis was 12.45 ± 6.17 days. The multivariable analyses showed that chemotherapy history, less activities and diabetes were the key risk factors for thrombosis. CONCLUSIONS: Peripherally inserted central venous catheters-related upper extremity venous thrombosis had high incidence rate, and most cases had no significant symptoms. The history of chemotherapy, less activities and diabetes were found to be the key risk factors. It should be routinely scanned in high-risk patients every 3-5 days after catheter insertion, which would then find blood clots in time and reduce the incidence of pulmonary embolism. RELEVANCE TO CLINICAL PRACTICE: Risk factors associated with peripherally inserted central venous catheters-related upper extremity venous thrombosis are of critical importance in improving the quality of patients' life. It is very important to grasp the indications to reduce the incidence rate of peripherally inserted central venous catheters-related upper extremity venous thrombosis.


Subject(s)
Arm/pathology , Catheterization, Peripheral/adverse effects , Neoplasms/complications , Venous Thrombosis/complications , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Risk Factors , Young Adult
14.
Biomed Environ Sci ; 26(7): 531-8, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23980301

ABSTRACT

OBJECTIVE: To evaluate whether waist circumference (WC) ≥85 cm is related to asymptomatic preclinical atherosclerosis in women from Shanghai, China. METHODS: A total of 2365 females aged ≥20 years recruited from 4 communities underwent physical examination and carotid artery scanning. Their carotid intima-media thickness (C-IMT) was measured. RESULTS: The C-IMT was significantly higher in overweight or obese women with their BMI ≥25.0 kg/m2(P<0.01) and in those with their WC ≥85 cm than in those with their WC <85 cm (P<0.01). Spearman and partial correlation analysis showed that the C-IMT was significantly correlated with WC which was independent of menopausal status. The C-IMT significantly increased with the increasing WC and reached to a platform in about 85 cm. An increment tendency was found in the subgroup with its WC <85 cm (P<0.01) while no significant tendency was found in the subgroup with its WC≥85 cm (P=0.07).Multiple stepwise regression analysis showed that the WC was an independent risk factor for C-IMT. In logistic regression model, the odd ratio of WC ≥80 cm, ≥80 cm and <85 cm and ≥85 cm for evaluating the risk of C-IMT elevation was 1.632, 1.501, and 1.878, respectively. CONCLUSION: WC is significantly correlated with C-IMT in women from Shanghai, China, and WC≥85 cm may be used in identifying the risk of subclinical carotid atherosclerosis.


Subject(s)
Carotid Artery Diseases/epidemiology , Carotid Intima-Media Thickness , Overweight/epidemiology , Waist Circumference , Adult , Aged , China/epidemiology , Cities , Female , Humans , Middle Aged , Risk Factors
15.
Cardiovasc Diabetol ; 12: 18, 2013 Jan 16.
Article in English | MEDLINE | ID: mdl-23324539

ABSTRACT

BACKGROUND: The features of carotid atherosclerosis in ketosis-onset diabetes have not been investigated. Our aim was to evaluate the prevalence and clinical characteristics of carotid atherosclerosis in newly diagnosed Chinese diabetic patients with ketosis but without islet-associated autoantibodies. METHODS: In total, 423 newly diagnosed Chinese patients with diabetes including 208 ketosis-onset diabetics without islet-associated autoantibodies, 215 non-ketotic type 2 diabetics and 79 control subjects without diabetes were studied. Carotid atherosclerosis was defined as the presence of atherosclerotic plaques in any of the carotid vessel segments. Carotid intima-media thickness (CIMT), carotid atherosclerotic plaque formation and stenosis were assessed and compared among the three groups based on Doppler ultrasound examination. The clinical features of carotid atherosclerotic lesions were analysed, and the risk factors associated with carotid atherosclerosis were evaluated using binary logistic regression in patients with diabetes. RESULTS: The prevalence of carotid atherosclerosis was significantly higher in the ketosis-onset diabetic group (30.80%) than in the control group (15.2%, p=0.020) after adjusting for age- and sex-related differences, but no significant difference was observed in comparison to the non-ketotic diabetic group (35.8%, p=0.487). The mean CIMT of the ketosis-onset diabetics (0.70±0.20 mm) was markedly higher than that of the control subjects (0.57±0.08 mm, p<0.001), but no significant difference was found compared with the non-ketotic type 2 diabetics (0.73±0.19 mm, p=0.582) after controlling for differences in age and sex. In both the ketosis-onset and the non-ketotic diabetes, the prevalence of carotid atherosclerosis was markedly increased with age (both p<0.001) after controlling for sex, but no sex difference was observed (p=0.479 and p=0.707, respectively) after controlling for age. In the ketosis-onset diabetics, the presence of carotid atherosclerosis was significantly associated with age, hypertension, low-density lipoprotein cholesterol and mean CIMT. CONCLUSIONS: The prevalence and risk of carotid atherosclerosis were significantly higher in the ketosis-onset diabetics than in the control subjects but similar to that in the non-ketotic type 2 diabetics. The characteristics of carotid atherosclerotic lesions in the ketosis-onset diabetics resembled those in the non-ketotic type 2 diabetics. Our findings support the classification of ketosis-onset diabetes as a subtype of type 2 diabetes.


Subject(s)
Carotid Artery Diseases/diagnosis , Carotid Artery Diseases/ethnology , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/ethnology , Diabetic Ketoacidosis/diagnosis , Diabetic Ketoacidosis/ethnology , Adult , Aged , Asian People/ethnology , Carotid Artery Diseases/epidemiology , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Prevalence , Risk Factors
16.
Zhonghua Yi Xue Za Zhi ; 90(27): 1897-901, 2010 Jul 20.
Article in Chinese | MEDLINE | ID: mdl-20979907

ABSTRACT

OBJECTIVE: To explore the value of color Doppler ultrasound in evaluating the therapeutic effects on ankylosing spondylitis (AS) patients. METHODS: Color Doppler high-frequency ultrasound images and blood flow in 30 healthy volunteers and 50 AS patients, changes of high-frequency ultrasound images and blood flow of involved sites in AS patients pre- and after-Etanercept treatments, as well as erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) and the Bath AS disease activity indices pre- and post-treatment were compared. RESULTS: Positive rates were significantly different between healthy volunteers and AS patients in terms of sacroiliac joints, Achilles tendon attachments, patellar ligament attachments, and rectus femoris tendon attachments by ultrasonograph (P < 0.05); and the fibular collateral ligament attachments positive rates had no significant difference with those at pre-treatment (P > 0.05). There was significant difference between patients with Bath AS disease activity index (BASDAI) ≥ 4 and those with BASDAI < 4 with respects to peripheral enthesis positive rate, Bath AS functional index (BASFI), patient's global assessment VAS (PGA), nocturnal back pain and general back pain VAS, morning stiffness duration, ESR and CRP (P < 0.05). Positive rates of sacroiliac joints, Achilles tendon attachments, patellar ligament attachments and rectus femoris tendon by ultrasonograph significantly decreased at Weeks 12 and 24 at post-treatment compared to that at pre-treatment (P < 0.05); there was significant difference for patient's BASDAI, BASFI, ESR and CRP at pre-treatment and weeks 12 and 24 post-treatment (P < 0.05). CONCLUSION: Ultrasound can sensitively detect the pathological changes of joint synovium and entheses so that it may be used as a routine method of monitoring diseases in these soft tissues, following up AS patients and evaluating clinical efficacy.


Subject(s)
Rheumatic Diseases/therapy , Sacroiliitis/therapy , Spondylitis, Ankylosing/diagnostic imaging , Spondylitis, Ankylosing/therapy , Ultrasonography, Doppler, Color , Adolescent , Adult , Case-Control Studies , Female , Humans , Male , Middle Aged , Tendons/diagnostic imaging , Treatment Outcome , Young Adult
17.
Adv Ther ; 26(4): 425-34, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19381521

ABSTRACT

Ultrasound contrast agents are not only effective in ultrasonic imaging but are also important tools for drug or gene delivery. Ultrasound beams can disrupt microbubbles and cell membranes, offering the opportunity to locally deliver drugs or genes. Liposome-shelled microbubbles have many advantages and are widely used in many applications, while Lipofectamine (Invitrogen, Life Technologies, Carlsbad, CA, USA), as a material of microbubble membranes, has been used to enhance the effects of gene delivery. Ultrasound contrast agents that have therapeutic effects can be used for treating peripheral vascular diseases, particularly in thrombotic and angiogenic diseases. A combination of targeted contrast agent and drug-carrying contrast agent may be safer and more effective in treating thrombosis. Vascular endothelial growth factor-loaded microbubbles are expected to treat a variety of neovascular diseases such as severe limb ischemia and other diseases. Although there are several limitations in the application of therapeutic ultrasound microbubble contrast agents, it will offer a new hope for the treatment of peripheral vascular disease.


Subject(s)
Contrast Media/therapeutic use , Microbubbles , Peripheral Vascular Diseases/therapy , Ultrasonic Therapy/methods , Albumins/therapeutic use , Chemistry, Pharmaceutical , Contrast Media/chemistry , Drug Delivery Systems/methods , Drug Delivery Systems/trends , Fluorocarbons/therapeutic use , Gene Transfer Techniques/trends , Humans , Indicators and Reagents/therapeutic use , Lipids/therapeutic use , Peripheral Vascular Diseases/diagnostic imaging , Phospholipids/therapeutic use , Polysaccharides/therapeutic use , Safety , Sulfur Hexafluoride/therapeutic use , Ultrasonic Therapy/trends , Ultrasonography/methods , Ultrasonography/trends , Vascular Endothelial Growth Factor A/therapeutic use
18.
Med Hypotheses ; 73(2): 211-2, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19328633

ABSTRACT

For the ability to carry drugs and release them at target areas, Ultrasound Contrast Agent (UCA) can be a new vector for drug delivery. Ultrasound makes UCA ruptured so that the drugs it carried can be released. The intensity of medical ultrasound varies wildly. Although low-intensity ultrasound is often used in vitro studies, we think in vivo, the application of high-intensity ultrasound will have better future prospects for drug delivery than low-intensity ultrasonic.


Subject(s)
Contrast Media , Drug Delivery Systems , Ultrasonics
19.
J Clin Ultrasound ; 36(4): 218-25, 2008 May.
Article in English | MEDLINE | ID: mdl-18335511

ABSTRACT

PURPOSE: To investigate the potential clinical application of tissue Doppler imaging (TDI) for motion measurement of the aortic wall in healthy and hypertensive adults. METHOD: We used TDI to examine 53 hypertensive and 29 sex-matched healthy adults. Maximum velocity of the first and second systolic wall expansion peaks (S1, S2), maximum velocity of early (D) and end (E) diastolic retraction velocity peaks, pulse wave transmit time (PWTT), and stiffness index (beta) of the abdominal aorta were measured and compared as for factors influencing vascular compliance, including age, sex, and blood pressure. RESULTS: Compared with the healthy subjects, the wall motion waveform of hypertensive patients showed absent E, mixed S1 and S2 peaks, and blunted S1. S1 and D were lower in hypertensive than in healthy subjects. Shortened PWTT and increased indicated increased aortic stiffness in both male and female hypertensive subects when compared with controls. Age, diastolic blood pressure (DBP) and sex were the significant independent factors modulating S1, while DBP and age were the significant independent factors modulating D. PWTT was independently influenced by age and systolic blood pressure. CONCLUSION: This study provides evidence that abdominal aortic wall motion measurement with TDI could demonstrate qualitative and quantitative wall motion features differentiating hypertensive from healthy adults. Wall motion velocity and PWTT could reflect abdominal aortic compliance changes related to age, sex, and blood pressure.


Subject(s)
Aorta, Abdominal/diagnostic imaging , Hypertension/diagnostic imaging , Ultrasonography, Doppler, Color , Adult , Aged , Aged, 80 and over , Aorta, Abdominal/physiology , Aorta, Abdominal/physiopathology , Diastole , Female , Humans , Hypertension/physiopathology , Male , Middle Aged , Regression Analysis , Systole
20.
J Clin Ultrasound ; 35(8): 458-61, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17486565

ABSTRACT

Budd-Chiari syndrome is a rare vascular complication of liver transplantation that may result in loss of the graft and a high mortality risk. Therefore, early diagnosis is extremely important to allow preservation of the graft and improve the prognosis. We describe the sonographic findings in a patient in whom Budd-Chiari syndrome occurred 2 days after orthotopic liver transplantation.


Subject(s)
Budd-Chiari Syndrome/diagnostic imaging , Liver Transplantation/adverse effects , Ultrasonography, Doppler, Color/methods , Blood Flow Velocity/physiology , Budd-Chiari Syndrome/etiology , Budd-Chiari Syndrome/physiopathology , Carcinoma, Hepatocellular/surgery , Humans , Liver Circulation , Liver Neoplasms/surgery , Male , Middle Aged , Severity of Illness Index , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...